EDF-2023-00231
-
Version actuelle du message - v3
-
Statut : ActifDate de publication : 29/10/2024 14:14:22Date de début : 20/12/2023 18:37:03Société : EDF
Taking into account key learnings from controls and repairs undertaken in 2023 on reactors linked to stress corrosion cracking, EDF considers that, in 2025, one planned outage out of three for the following reactors may be extended by an average of 30 days.
The reactors concerned are: BEL1, BEL2, BLA2, BLA4, BUG2, CAT1, CAT3, CHB1, CHO1, CRU1, CRU2, DAM1, DAM2, DAM3, FLA2, GOL2, GRA1, GRA2, GRA4, NOG1, SLB1, TRI1, TRI2.
-
-
Version antérieure du message - v2
-
Statut : InactifDate de publication : 24/07/2024 10:51:39Date de début : 20/12/2023 18:37:03Société : EDF
Taking into account key learnings from controls and repairs undertaken in 2023 on reactors linked to stress corrosion cracking, EDF considers that, in 2025, one planned outage out of three for the following reactors may be extended by an average of 30 days.
The reactors concerned are: BEL1, BLA2, BLA4, BUG2, CAT1, CAT3, CHB1, CHO1, CIV2, CRU1, CRU2, DAM1, DAM2, DAM3, FLA2, GOL2, GRA1, GRA2, GRA4, NOG1, SLB1, TRI1, TRI2.
-
-
Version antérieure du message - v1
-
Statut : InactifDate de publication : 20/12/2023 18:37:53Date de début : 20/12/2023 18:37:03Société : EDF
Taking into account key learnings from controls and repairs undertaken in 2023 on reactors linked to stress corrosion cracking, EDF considers that, in 2025, one planned outage out of three for the following reactors may be extended by an average of 30 days.
The reactors concerned are: BLA4, BUG2, CAT1, CHB1, CHO1, CIV2, CRU1, DAM1, FLA2, GOL2, GRA1, GRA6, SLB1.
-